Abstract
This work studies the use of ultrasonic imaging as an evaluation tool in concrete subjected to freeze–thaw (F–T) cycles. To evaluate the damage in this deterioration process, ultrasonic velocity and attenuation images have been generated from concrete specimens with and without air-entraining agents. Two parameters have been proposed from these ultrasonic images according to our experimental setup: the non-assessable area proportion (NAAP) and a weighted average velocity in terms of the NAAP. The proposed parameters have been compared with the recommended failure criteria of the ASTM and Rilem standards, which employ ultrasonic contact measurements. The principal advantage of the use of ultrasonic images and the proposed methodology in comparison with the ultrasonic velocity measurements by contact is the possibility of detection of incipient damage caused by accelerated freeze–thaw cycles.
Accepted Version (Free)
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.