Abstract

The reported work has been performed in order to establish the measurement traceability of high frequency capacitance standards at CSIR-NPL. In this context, four-terminal-pair air capacitance standards of Agilent 16380A type with nominal values of 1pF, 10pF, 100pF and 1000pF have been evaluated at a set of frequencies ranging from 10kHz to 30MHz. The evaluation procedure involves the determination of capacitive and inductive residual components of an electrical equivalent circuit model of these standards. The versatile measurement automation program has been developed to control the evaluation procedure and the functionality of the same has been discussed in the paper.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.