Abstract

Four platelet compatibility assays were performed on serum and platelet or lymphocyte samples from 38 closely HLA-matched donor/recipient pairs involved in 55 single-donor platelet transfusions. The 22 patients studied were refractory to transfusions of pooled random-donor platelets. Of the four assays (platelet suspension immunofluorescence, PSIFT; 51Cr release; microlymphocytotoxicity; and a monoclonal anti-IgG assay, MAIA), the MAIA was most predictive of platelet transfusion outcome (predictability, 74% for one-hour posttransfusion platelet recovery and 76% for 24-hour recovery). The only other assay to reach statistical significance was the PSIFT (63% predictability for one-hour posttransfusion recovery). The degree of HLA compatibility between donor and recipient (exact matches v those utilizing cross-reactive associations) was unrelated to the ability of the MAIA to predict transfusion results. The MAIA may be capable of differentiating HLA antibodies, ABO antibodies, and platelet-specific antibodies responsible for failure of HLA-matched and selectively mismatched single-donor platelet transfusions.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.