Abstract

To evaluate fetal ventricular diastolic function in pregnancies of women with gestational diabetes (GD), to determine whether minimal anomalies of glucose metabolism may influence fetal cardiac function. Fetal ventricular filling time was measured by transabdominal ultrasound in singleton pregnancies between 34 and 37weeks of gestation. We used a measurement which consists in the ratio between the diastolic time and the whole cardiac cycle time. The study included 35 women with a GD and 217 non-diabetic. Right ventricular filling time (RVFT) was significantly lower in the GD group (mean of RVFT = 39.2 ± 4.4 vs 43.6 ± 4.6; p < 0.01). Likewise, left ventricular filling time (LVFT) was shorter in the GD group compared to the non-GD group, though the difference was not significant (mean of LVFT = 43.6 ± 4.6 vs 44.6 ± 5.5; p = 0.33). Fetal right cardiac function is altered also in pregnancies where gestational diabetes is well controlled.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.