Abstract
While new technologies are being developed for extracting unconventional oil, in the near term economic benefits and footprint reduction can be achieved by enhancing the energy efficiency of existing facilities. The objective of this work is to evaluate energy efficiency opportunities for in situ extraction of Canada's oil sands resource using pinch analysis. Modifications to an original plant design are analyzed in order to estimate utility savings beyond those obtained for the initial process configuration. The modifications explored in this paper are estimated to deliver energy savings of up to 6% beyond ‘business as usual’. This corresponds to GHG emissions reduction of approximately 5%. However, in some cases, this increase in energy savings comes at the cost of increasing demand for make-up water and volume of disposal water. Surplus generation of steam beyond heating requirements in the water treatment system leads to energy inefficiencies. Additional cost and energy savings are obtained by reducing or eliminating the use of glycol in the cooling circuit.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.