Abstract
This work is aimed to analyze the EM internal forces distribution on the blanket system (blankets modules and segment back supporting structure) of the EU PPPT DEMO 2015 reactor configuration. In order to validate their impact on the segment structure, an EM analysis is conducted using a simplified plasma central disruption. The calculated Lorentz’s forces distributions are then used as input for structural analyses focusing on the mechanical integrity of the segment back supporting structure. In particular, the electrical and structural assumptions used in this work are based on the HCPB blanket design developed at the Karlsruhe Institute of Technology. A preliminary assessment of the primary stresses according the design code RCC-MRx indicates the ability of the segments to resist the EM forces, where the lowest margin is given by the immediate plastic instability criterion on the inboard segment with 14%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.