Abstract

A fast and simple method for the extraction of deoxynivalenol (DON) from wheat flour using dispersive liquid–liquid microextraction (DLLME) followed by high-performance liquid chromatography–UV detection has been developed and compared with immunoaffinity column cleanup (IAC) process. The influence of several important parameters on the extraction efficacy was studied. Under optimized conditions, a linear calibration curve was obtained in the range of 50–1,000 μg/L. Average recoveries of DON from spiked wheat samples at levels of 500 μg/kg for DLLME and IAC ranged from 72.9 ± 1.6 and 85.5 ± 3.1, respectively. A good correlation was found for spiked samples between DLLME and IAC methods. The limit of detection was 125 and 50 μg/kg for DLLME and IAC method, respectively. Advantages of DLLME method with respect to the IAC have been pointed out.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.