Abstract

ABSTRACTAnalysis of differential pore-volume distribution (DPVD) patterns of a commercial Clinoptilolite has been conducted experimentally using an analyzer by measuring the N2 adsorption isotherm. The commercial material was fractionated by sieving through sequential sieves: <125 µ (Z8; fine), 125–250 µ (Z9; medium), and >250 µ (Z10; coarse). The DPVD of the fractions were calculated from the hysteresis loop according to the adsorption and desorption curves of Dollimore-Heal (DH) model. The adsorption cycle had produced dissimilar differential pore volume distribution patterns. For the 10-nm pore width, fine and medium fractions had a maximum pore volume up to 0.0016 cm3/g nm, while the coarse fraction had a little greater value up to 0.002 cm3/g nm. Moreover, the medium fraction had too many hills and valleys in the DPVD. However, the desorption cycle–based DH analysis did not show any marked variation in the DPVD pattern.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call