Abstract

The nucleotide alignment of all 11 genes of human Rotavirus A (RVA) strains revealed suitability of NSP2, NSP3 and VP6 genes for the development of real time PCR (qRT-PCR). Evaluation of qRT-PCR assays using known rotavirus ELISA positive and negative fecal specimens showed non-overlapping ranges of Mean ±3SD cycle threshold (Ct) values for NSP3 and VP6 based assays. Using serial dilutions of purified RVA, high sensitivity of VP6 qRT-PCR assay (1.95 × 10−5 pg/μL of RNA) was recorded as compared to NSP2 and NSP3 qRT-PCR assays (1.95 × 10-4 pg/μL of RNA). Further, evaluation of the VP6 qRT-PCR assay involving 266 fecal specimens and frequency polygon analysis of the data indicated cut-off value of 35 for Ct with high sensitivity (126/131, 96%) and specificity (12/12, 100%). This VP6 qRT-PCR assay will be a useful diagnostic tool to evaluate clinical presentations in rotaviral gastroenteritis under different conditions such as breast feeding and administration of rotavirus vaccines.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.