Abstract

ObjectivesThis clinical study aimed to investigate the outcomes and survival rates of different variations of inlay-retained fixed dental prostheses (IR-FDPs) composed of monolithic zirconia ceramic. The IR-FDPs with a single-retainer design were used for replacing missing mandibular second premolars. The research evaluated the effectiveness and longevity of these prostheses in clinical settings. MethodsA total of 30 IR-FDPs (n = 30) were placed for 27 female patients who presented with missing mandibular second premolar teeth. For this study, the mandibular first molar was chosen as a retainer for the cantilever IR-FDPs and the study involved a random assignment of participants into three distinct groups, each comprising 10 individuals (n = 10). The criterion for the grouping was the retainer design: inlay ring (IR), lingual coverage (LC), and occlusal coverage (OC). The three groups included mesial inlay box with the same dimensions (3 mm height, 3 mm width and 2 mm depth). All IR-FDPs were manufactured using monolithic high translucent 3Y zirconia and the connector area to the cantilever pontic was adjusted to dimensions of 3 × 3 mm for all designs. The restorations were bonded using adhesive resin cement. The clinical and radiographic evaluations of the restorations were conducted for a duration of 18 months, following the modified FDI (World Dental Federation) criteria. ResultsThe restorations were observed in stage one for a period of 18 months. Only one restoration in group LC was debonded after 10 months and re-bonded. The clinical quality of all crowns and the patient's satisfaction were high. No adverse soft tissue reactions around the crowns were observed and only one abutment in group IR was endodontically treated after 12 months. ConclusionsZirconia cantilever IR-FDPs offer a viable short-term treatment option for replacing missing posterior teeth, providing esthetic and functional benefits while minimizing invasiveness. Over an 18-month observation period, these prostheses have demonstrated a remarkable survival rate of 100% and a success rate of 96.6%. These findings suggest the effectiveness and reliability of zirconia cantilever IR-FDPs as a short-term solution for replacing missing posterior teeth. Clinical significanceZirconia cantilever IR-FDPs could present a practical solution for addressing posterior tooth loss, especially in cases where implant placement is not recommended and conventional fixed dental prostheses entail excessive invasiveness.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call