Abstract
Three adsorbents (Chelex-100, manganese dioxide [MnO2] and Metsorb), used as binding layers with the diffusive gradient in thin film (DGT) technique, were evaluated for the measurement of inorganic uranium species in synthetic and natural waters. Uranium (U) was found to be quantitatively accumulated in solution (10–100μgL−1) by all three adsorbents (uptake efficiencies of 80–99%) with elution efficiencies of 80% (Chelex-100), 84% (MnO2) and 83% (Metsorb). Consistent uptake occurred over pH (5–9), with only MnO2 affected by pH<5, and ionic strength (0.001–1molL−1 NaNO3) ranges typical of natural waters, including seawater. DGT validation experiments (5 days) gave linear mass uptake over time (R2≥0.97) for all three adsorbents in low ionic strength solution (0.01M NaNO3). Validation experiments in artificial sea water gave linear mass uptake for Metsorb (R2≥0.9954) up to 12h and MnO2 (R2≥0.9259) up to 24h. Chelex-100 demonstrated no linear mass uptake in artificial sea water after 8h. Possible interferences were investigated with SO42− (0.02–200mgL−1) having little affect on any of the three DGT binding layers. PO43− additions (5μgL−1–5mgL−1) interfered by forming anionic uranyl phosphate complexes that Chelex-100 was unable to accumulate, or by directly competing with the uranyl species for binding sites, as with MnO2 and the Metsorb. HCO3− (0.1–500mgL−1) additions formed anionic species which interfered with the performance of the Chelex-100 and the MnO2, and the Ca2+ (0.1–500mgL−1) had the affect of forming labile calcium uranyl species which aided uptake of U by all three resins. DGT field deployments in sea water (Southampton Water, UK) gave a linear mass uptake of U over time with Metsorb and MnO2 (4 days). Field deployments in fresh water (River Lambourn, UK) gave linear uptake for up to 7 and 4 days for Metsorb and MnO2 respectively. Field deployment of the Metsorb-DGT samplers with various diffusive layer thicknesses (0.015–0.175cm) allowed accurate measurements of the diffusive boundary layer (DBL) and allowed DBL corrected concentrations to be determined. This DBL-corrected U concentration was half that determined when the effect of the DBL was not considered. The ability of the DGT devices to measure U isotopic ratios with no isotopic fractionation was shown by all three resins, thereby proving the usefulness of the technique for environmental monitoring purposes.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.