Abstract

Background: Achieving maximum anchorage without movement of the teeth in anchorage unit has been a great challenge in orthodontics and the success of the treatment plan highly depends on it. In this case, using orthodontic mini-implants can make a huge difference. The objective of this retrospective study was to measure thickness of cortical bone at prospective mini-implant placement sites in mandible in order to understand stability aspects of mini-implant placement by using cone-beam computed tomography (CBCT) images. Materials and Methods: Initial 3-dimensional images of 40 adult patients were studied. The cortical bone thickness was obtained at the alveolar processes from canine to second molar at 5 different vertical levels from the cementoenamel junction (CEJ). To determine the cortical bone thickness, tangent lines were drawn buccolingually to the roots in axial section and a third line was drawn from the middle of these two lines, and the cortical bone thickness was measured where the third line crossed the buccal cortex. Results: Mandibular and buccal cortical bone thicknesses were 0.79 to 2.49 mm, respectively. There was a statistically significant increase from the CEJ to the apex (P<0.001), while this increase was not statically significant at interdental area of teeth #3 and #4. Comparing the 4 mm section in all sites showed significant increase from anterior to posterior. Conclusion: Based on our results, the cortical bone thickness mostly follows a pattern and depends on the interradicular site rather than individual differences. Key words: Cone-beam computed tomography; orthodontic anchorage procedures

Highlights

  • Use of an appropriate anchorage is one of the important factors in achieving successful results in fixed orthodontics

  • Success in extra oral anchorage techniques depends on patient cooperation and with the use of these techniques, even under the best condition, some unfavorable movements usually occur in the anchorage unit [2]

  • Provision of an appropriate anchorage has been one of the main concerns in orthodontic treatment planning until 1997, when Kanomi reported the use of orthodontic mini-implants for tooth movements, providing an all-bone anchorage and easy placement and removal [3]

Read more

Summary

Introduction

Use of an appropriate anchorage is one of the important factors in achieving successful results in fixed orthodontics. Provision of an appropriate anchorage has been one of the main concerns in orthodontic treatment planning until 1997, when Kanomi reported the use of orthodontic mini-implants for tooth movements, providing an all-bone anchorage and easy placement and removal [3]. Achieving maximum anchorage without movement of the teeth in anchorage unit has been a great challenge in orthodontics and the success of the treatment plan highly depends on it. In this case, using orthodontic mini-implants can make a huge difference. Conclusion: Based on our results, the cortical bone thickness mostly follows a pattern and depends on the interradicular site rather than individual differences

Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.