BackgroundTo investigate the feasibility of compressed sensing and parallel imaging (CS-PI)-accelerated bowel motility magnetic resonance imaging (MRI) and to compare its image quality and diagnostic quality to conventional sensitivity encoding (SENSE) accelerated scans.MethodsBowel MRI was performed in six volunteers using a three-dimensional balanced fast field-echo sequence. Static scans were performed after the administration of a spasmolytic agent to prevent bowel motion artefacts. Fully sampled reference scans and multiple prospectively 3× to 7× undersampled CS-PI and SENSE scans were acquired. Additionally, fully sampled CS-PI and SENSE scans were retrospectively undersampled and reconstructed. Dynamic scans were performed using 5× to 7× accelerated scans in the presence of bowel motion. Retrospectively, undersampled scans were compared to fully sampled scans using structural similarity indices. All reconstructions were visually assessed for image quality and diagnostic quality by two radiologists.ResultsFor static imaging, the performance of CS-PI was lower than that of fully sampled and SENSE scans: the diagnostic quality was assessed as adequate or good for 100% of fully sampled scans, 95% of SENSE, but only for 55% of CS-PI scans. For dynamic imaging, CS-PI image quality was scored similar to SENSE at high acceleration. Diagnostic quality of all scans was scored as adequate or good; 55% of CS-PI and 83% of SENSE scans were scored as good.ConclusionCompared to SENSE, current implementation of CS-PI performed less or equally good in terms of image quality and diagnostic quality. CS-PI did not show advantages over SENSE for three-dimensional bowel motility imaging.

Highlights

  • To investigate the feasibility of compressed sensing and parallel imaging (CS-PI)-accelerated bowel motility magnetic resonance imaging (MRI) and to compare its image quality and diagnostic quality to conventional sensitivity encoding (SENSE) accelerated scans

  • Mean structural similarity index measure (SSIM) values barely differed between examined acceleration factors, in both SENSE and CS-PI

  • Scores regarding image quality of the prospectively undersampled scans obtained by visual assessment were largely similar to the scores from their retrospective counterparts (Fig. 5)

Read more

Summary

Introduction

To investigate the feasibility of compressed sensing and parallel imaging (CS-PI)-accelerated bowel motility magnetic resonance imaging (MRI) and to compare its image quality and diagnostic quality to conventional sensitivity encoding (SENSE) accelerated scans. Intestinal motility frequently becomes deranged in diseases such as Crohn’s disease and Chronic Intestinal. The resulting hypo-motility in Crohn’s disease and the global pan-enteric changes as seen in chronic intestinal pseudo-obstruction are considered powerful biomarkers to monitor the disease process [1–6]. To overcome the abovementioned problems, magnetic resonance imaging (MRI) has been introduced as a non-invasive technique to assess bowel motility. Jonge et al European Radiology Experimental (2019) 3:7 motion analysis software [2–7]. Despite these advances, technological challenges with respect to image acquisition remain

Objectives
Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.