Abstract

In the compliance control of concrete, different types of criterion are in use. In particular, compound criteria are often used since this type of criterion appears in the CEB-FIP Model Code for Concrete Structures. In this paper, the dependency between the minimumvalue and the mean-value criteria is shown not to be negligible. The usefulness of a minimum-value criterion is questioned, as generally it unnecessarily decreases the probability of acceptance for low defective fractions. The preliminary application of an outlier criterion is suggested as a more consistent approach. Finally, criteria of the type\(\bar x_n \geqslant f_{ck} + \lambda s_n \) are proposed, where the numerical values of λ are fixed in such a way that the resulting OC lines are tangent to a continuous boundary line for the unsafe region.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.