Abstract

AbstractAbstract 3678 Introduction:Thrombotic thrombocytopenic purpura (TTP) is characterized by microthrombi, hemolytic anemia as well as thrombocytopenia. These symptoms are caused by a decreased activity of the protease ADAMTS13 which cleaves the von Willebrand Factor (VWF), due to mutation of the ADAMTS13-gene or autoantibodies. At the moment, the only available immediate therapy is plasmapheresis with Fresh Frozen Plasma (FFP) which may induce side effects. Therefore an alternative therapy might be the treatment with clotting factor concentrates. Methods:40 plasma samples were tested, consisting of FFP and solvent/detergent treated plasma, four batches of each blood group; VWF/VIII concentrates (Wilate®; Wilfactin®; Haemate®P; Immunate®; Kogenate®, Beriate®). In all samples ADAMTS13 activity, antigen and autoantibodies against ADAMTS13 were investigated. Additionally, the samples were tested for the presence of ultralarge VWF multimers. The BCS method according to Böhm, two ELISAs (Technozym®ADAMTS13 and Actifluor™ADAMTS13) and the electrophoresis on a SDS gel were used. Results:ADAMTS13 activity was found in all VWF)VIII concentrates, which are produced from human plasma, but only with a very low activity (Wilate® 5.6%; Wilfactin® 2.8%; Haemate®P 13%; Immunate® 3.7%). ADAMTS13 activity was not detectable in the factor VIII concentrates (Kogenate® <2%; Beriate® <2%). Usual FFP and solvent/detergent treated plasma samples, contained much higher ADAMTS13 activity and antigen values than concentrates (FFP 78.6%, solvent/detergent treated plasma 77.6%). However a difference of activity between individual blood groups was evident in FFP samples (blood group A 69.4%; B 64.9%; AB 98.1%; 0 82.0%). Ultralarge VWF multimers could be demonstrated in VWF containing concentrates, less in VIII concentrate from human plasma and not in FFP and solvent/detergent treated plasma samples. As expected recombinant-produced VIII concentrate contained no traces of ultralarge VWF. In all analyzed samples antibodies were negative. Conclusion:For therapy of TTP clotting factor concentrates cannot be used as an alternative to the usual FFP and solvent/detergent treated plasma, because their ADAMTS13 activity values are too low.In addition, the VWF/VIII concentrates contain higher quantities of ultralarge VWF multimers, which are contraindicated for TTP patients. The differences of ADAMTS13 activity in FFP samples varies between the individual blood groups and batches. Solvent/detergent treated plasma shows less variation in ADAMTS13 activity due to the manufacturing process involving plasma pooling. Disclosures:No relevant conflicts of interest to declare.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.