Abstract

The surface modifications in teeth increase the retentive strength of cemented castings by providing micro as well as macro retentive ridge and groove patterns. Restoring the dental implants with cement-retained prosthesis is well known. Therefore, it is of interest to compare retentive property of implant abutments with and without circumferential grooves. Hence, 20 straight shoulder type titanium abutments were with abutment screws as well as prefabricated plastic copings and corresponding 12 mm-long stainless steel laboratory implant analogs were used. The abutments were divided into two subgroups of 10 abutments each: without grooves and with grooves. After thermocycling and storing the cemented abutments in water at 37°C water for 6 days they were assembled in the Universal testing machine and subjected to a pullout test (retention) at a crosshead speed of 5.0mm/min to record forces in Newton. Data suggest that the addition of grooves increased the retention. The mean retentive forces of standard machined abutments (plain) cemented with Resin modified GIC showed 339.34 N. Retention increased by 667.39N after addition of circumferential grooves. The surface modification of an implant abutment by means of circumferential grooves is an effective method of improving the retention of cast crowns cemented with resin modified GIC especially in short abutments.

Highlights

  • The success of oral rehabilitation of dental implants depends on osseointegration and on maintenance of the prosthesis on the implant abutment [1,2,3,4]

  • The surface modification of an implant abutment by means of circumferential grooves is an effective method of improving the retention of cast crowns cemented with resin modified GIC especially in short abutments

  • It was apparent that the circumferential grooves increased the retention

Read more

Summary

Evaluation of change in implant abutment after teeth surface modifications

Khushbu Mishra1,*, Priya singh, Mohammad Kashif Noorani, Kumar Adarsh, Mohammad Nabeel Kalburgi, Manisha Mallik. The authors undertake that they are not associated with any other third party (governmental or non-governmental agencies) linking with any form of unethical issues connecting to this publication. The authors declare that they are not withholding any information that is misleading to the publisher in regard to this article. Author responsibility: The authors are responsible for the content of this article. The editorial and the publisher have taken reasonable steps to check the content of the article in accordance to publishing ethics with adequate peer reviews deposited at PUBLONS. Declaration on official E-mail: The corresponding author declares that official e-mail from their institution is not available for all authors

Background
Results and Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call