Abstract

To determine the presence of bacterial biofilm on nylon sutures removed from clinically noninfected eyes after cataract surgery. The Eye Institute, Tan Tock Seng Hospital, Singapore, Singapore. Sutures were removed from 10 eyes after cataract surgery at different time periods. Immediately after removal, the sutures were fixed and dehydrated. All sutures were viewed by scanning electron microscopy, and 6 were also viewed by transmission electron microscopy (TEM). There was no evidence of bacterial biofilm formation on the nylon sutures. Significant cellular debris was seen, mainly at the knots. Clusters of coccoid-shaped structures were visible; however, examination by TEM showed they were not bacteria. There was no evidence of biofilm formation on sutures removed after cataract surgery from clinically noninfected eyes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.