Abstract

AbstractFour bilayer tablet compression machines were evaluated for their suitability for compression of a specific bilayer tablet formulation. Tablet machines evaluated were: Manesty (Model No. BB4), Manesty (Model No. Rotappress), Fette (Model No. P3102) and Kilian (Model No. 51AST-ZS) tablet presses. The tablet delamination tendency was the primary acceptance criteria for the evaluation of tablet press performance. The compression force on layer I was found to be the major factor influencing tablet delamination. It was found that the Kilian press was best suited for the compression of the model bilayer tablet formulation. The Kilian press is equipped with a special sampling device for layer I which allows additional compression force to be applied on layer I only at the time of weight sampling. The sampling device then returns to the original set points after sampling is completed. This feature maintains the compression force on layer I to a minimum during routine compression. Data indicated that the c...

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.