Abstract

Concrete filled steel tube (CFT) members have been applied to the columns of rigid frame structures. However, the failure mode, the bending capacity and deformation performance of CFT members with small shear-span ratio are not clear because there have been few studies on them. In this study, cyclic loading tests were conducted on short-column CFT members with constant vertical loads. As a result, it was confirmed that they show a flexural failure mode, but the existing design method overestimates their bending capacity. Therefore, a new evaluation method was proposed for their bending capacity and deformation performance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.