Abstract

In order to evaluate the stress and working performance of a reinforced stone arch bridge, the load test of the bridge is carried out. Static load test is to test the stress and displacement of each section of the main arch ring under the action of partial load and medium load. The results show that under the action of various loads, the check coefficients of deflection and strain of this bridge do not exceed the specification limit of 1.0 of masonry arch bridge, the actual working performance of the structure is good, the maximum value of relative residual strain and relative residual deformation are 11.11% and 8.21% respectively, and they do not exceed the standard allowable value of 20%, and the whole bridge is in the elastic deformation stage. The test results show that the reinforcement method of thickening the main arch ring has good application value, can effectively improve the service level of the old bridge and prolong the safety service life, and has obvious social and economic benefits.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.