Abstract

In this study, the propensities of reservoir fluids sampled from South America to precipitate asphaltenes under realistic production conditions of pressure, temperature and/or composition (e.g. lift gas operation and chemical treatment) were evaluated. Novel techniques, namely a laser-based solids detection system (SDS) and a high pressure microscopy (HPM) coupled with in-house imaging software package for particle size analyses, have been simultaneously used to measure and compare the incipient conditions for precipitation of asphaltenes from live oils as well as the associated morphological and size distribution changes. The combination of qualitative information such as particle morphology and quantitative data such as particle size distribution was particularly very valuable in evaluating the effectiveness of Asphaltene Inhibitors (AI).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.