Abstract
Groundwater potential and aquifer protective capacity of the overburden unit was evaluated in part of Iju, Akure North, Ondo State using integrated geophysical methods involving Very Low Frequency Electromagnetic (VLF-EM) profiling and Vertical Electrical Sounding (VES). Four major traverses were established of varying length extents. The VLF-EM measurements were taken along the four major profiles of 10 m station interval.Forty two (42) Vertical Electrical Soundings were also conducted with half electrode spacing varying between 1 and 100 m and interpretation was done using the partial curve matching techniques and computer aided iteration. Five subsurface geological units were identified from geoelectric sections, consisting of the top soil, lateritic, weathered, partly weathered and fresh basement layers consecutively. For the first layer, resistivityranges between 23 and 323 Ωm with values of thickness ranging between 0.5 and 2.2 m. The resistivity and thickness of the second (lateritic) layer range from 132 to 430 Ωm and 1.6 to 4 m respectively. The resistivity of the weathered layer ranges from 4 to 94 Ωm and variable thickness between 10 and 24.4 m. The fourth layer has a resistivity value range of 65 to 120 Ωm and thicknesses between 20 and 30 m. The basement bedrock (fifth layer) has resistivity values between 770 and 820 Ωm. The depth to bedrock ranges from 1.8 to 31 m. The geophysical data and the basement aquifer delineated were then used to evaluate the hydrogeological setting and aquifer protective capacity of the study area. The observation from the results shows that close to 70 % of the study area falls within the zones of low groundwater potential, 25 % falls within medium potential zones while only 5 % make up the high potential zones. 75 % of the study area constituted the weak to poor protective capacity zones.
Highlights
Vertical Electrical Sounding Type Curves The curve types obtained in the study area generally varies from H, KH, HA and HKH
The Very Low Frequency Electromagnetic (VLF-EM) and Vertical Electrical Sounding (VES) results generated have been used to assess the potential of groundwater and aquifer vulnerability within the area of study
The larger part of the area of study is situated within low groundwater potential zones, 25 % falls within medium potential zones while only 5 % constitute the high potential zones
Summary
The third lithologic unit is composed of weathered layer, with resistivity values ranges from 4 – 94 Ωm. Resistivity values of the weathered layer showed clay to sandy clay and clayey sand lithologic units. The fourth layer delineated beneath VES 6 along Traverse 1 shows partly weathered/fractured basement, with resistivity value of 65 Ωm. The overburden thickness beneath VES 14 and 20 is expected to contribute to the groundwater yield of the aquifer, with overburden thickness of 35 m and 33.6 m respectively. These can be considered for siting of shallow borehole (Table 2)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of the Nigerian Society of Physical Sciences
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.