Abstract
To evaluate an external quality assessment (EQA) program for human immunodeficiency virus (HIV) rapid diagnostics testing by the Haitian National Public Health Laboratory (French acronym: LNSP). Acceptable performance was defined as any proficiency testing (PT) score more than 80%. The PT database was reviewed and analyzed to assess the testing performance of the participating laboratories and the impact of the program over time. A total of 242 laboratories participated in the EQA program from 2006 through 2011; participation increased from 70 laboratories in 2006 to 159 in 2011. In 2006, 49 (70%) laboratories had a PT score of 80% or above; by 2011, 145 (97.5%) laboratories were proficient (P < .05). The EQA program for HIV testing ensures quality of testing and allowed the LNSP to document improvements in the quality of HIV rapid testing over time.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.