Abstract

In this paper, the sensitization of aged Incoloy 800 alloy to intergranular corrosion has been systemically investigated by double loop electrochemical potentiokinetic reactivation (DL-EPR) technique in combination with oxalic acid etching test and microstructure observation. The DL-EPR results show that the specimens aged at 650 °C and 700 °C for 4 h were intensely sensitized with I r: I a value greater than 30% while there was no sensitization phenomenon for the specimens aged at 800 °C for 4 h. It was also found that the degree of sensitization increased gradually with the aging time in the range of 0–10 h at 650 °C, and I r: I a value reached the maximum −46% after an aging time of 10 h. However, further increasing aging time decreased the sensitization due to the healing effect incurred by the diffusion of chromium from adjacent grains to chromium-depleted zones. Comparison between two evaluating techniques (the DL-EPR and oxalic acid etching test) has also been conducted.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.