Abstract

This study was designed to evaluate the possibility of monitoring Mycobacterium tuberculosis infection using a serological assay. A discriminant score comprising antigen fractions of 38, 28, 24 and 19 kDa, identified in western blots using the Mycobacterium bovis bacille Calmette-Guérin (BCG) A60 antigen complex was established in a sample of 57 purified protein derivative (PPD)-negative and 47 PPD-positive individuals. It was then tested in a group of 140 subjects undergoing BCG vaccination as a model of tuberculosis complex infection and in a group of human immunodeficiency virus (HIV)-infected individuals as a model of cell-mediated immunodeficiency-related risk of tuberculosis. The discriminant score identified 57 out of 57 (100%) PPD-positives and none (0%) of the 47 PPD-negatives. In the BCG vaccinated subjects, 1.4% tested positive before vaccination and 90% after vaccination. In the HIV-positive subjects, 90% of the PPD-positive and 5% of the PPD-negative subjects had a positive score. This study suggests that the western blot discriminant score is an accurate test to survey M. tuberculosis infection in serum samples.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.