Abstract

Cell culture titres are expected to increase still further over the forthcoming years. This imposes challenges for downstream processing including the potential need to use larger volumes of chromatography resins. Such a move could create throughput bottlenecks because of the compressible nature of many commercially available resins, which makes the operation of columns with diameters beyond 2m infeasible due to resin collapse. The use of cylindrical inserts of negligible thickness has been proposed in the literature as a way to enhance the level of wall support, allowing higher superficial flow velocities to be applied and hence larger diameter columns to be used. In this study, a structural mechanics model has been developed to evaluate the effect of inserts on the column pressure drop and flow characteristics. Simulations were shown to be in good agreement with published experimental data. The model was then used to predict the effect of insert number, diameter, height and roughness on critical velocity of manufacturing scale columns.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.