Abstract

In this study, the effect of using a hybrid solar thermal-activated adsorption desalination system for brackish water is evaluated under the climatic conditions of the Brazilian semiarid region. The proposed theoretical model utilizes climatic data from the meteorological station in Campina Grande, PB, and adsorptive kinetics data of Fuji Davison RD 260 silica gel to predict the performance indices of the specific daily water production (SDWP), specific cooling power (SCP), and coefficient of performance (COP) performance coefficients over a characteristic day. The SDWP value of 6.26 m3/ton, SCP ranging from 50 to 300 W/kg, and an average COP of 0.5 were obtained, considering variations in global horizontal irradiance in the ACDS system and transient ambient temperature. It was observed that both the production of desalinated water and the refrigeration effect increase with the rise in daily solar irradiance. The variation in the number of solar collectors used in the system and their optimality, as well as the variation in the salinity index of the feed source, impacted the evaluated performance coefficients.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.