Abstract

One of the main drawbacks of Cone Beam Computed Tomography (CBCT) is the contribution of the scattered photons due to the object and the detector. Scattered photons are deflected from their original path after their interaction with the object. This additional contribution of the scattered photons results in increased measured intensities, since the scattered intensity simply adds to the transmitted intensity. This effect is seen as an overestimation in the measured intensity thus corresponding to an underestimation of absorption. This results in artifacts like cupping, shading, streaks etc. on the reconstructed images. Moreover, the scattered radiation provides a bias for the quantitative tomography reconstruction (for example atomic number and volumic mass measurement with dual-energy technique). The effect can be significant and difficult in the range of MeV energy using large objects due to higher Scatter to Primary Ratio (SPR). Additionally, the incident high energy photons which are scattered by the Compton effect are more forward directed and hence more likely to reach the detector. Moreover, for MeV energy range, the contribution of the photons produced by pair production and Bremsstrahlung process also becomes important. We propose an evaluation of a scattering correction technique based on the method named Scatter Kernel Superposition (SKS). The algorithm uses a continuously thickness-adapted kernels method. The analytical parameterizations of the scatter kernels are derived in terms of material thickness, to form continuously thickness-adapted kernel maps in order to correct the projections. This approach has proved to be efficient in producing better sampling of the kernels with respect to the object thickness. This technique offers applicability over a wide range of imaging conditions and gives users an additional advantage. Moreover, since no extra hardware is required by this approach, it forms a major advantage especially in those cases where experimental complexities must be avoided. This approach has been previously tested successfully in the energy range of 100 keV – 6 MeV. In this paper, the kernels are simulated using MCNP in order to take into account both photons and electronic processes in scattering radiation contribution. We present scatter correction results on a large object scanned with a 9 MeV linear accelerator.

Highlights

  • One of the main drawbacks of MeV energy range Cone Beam Computed Tomography (CBCT) is scattering of photons inside the object and the detector

  • One of the main drawbacks of MeV energy range CBCT is scattering of photons inside the object and the detector

  • This effect is seen in the back projection reconstruction algorithms as overestimated reconstructed linear attenuation corresponding to an underestimation of absorption

Read more

Summary

INTRODUCTION

One of the main drawbacks of MeV energy range CBCT is scattering of photons inside the object and the detector. In case of MeV energy range, forward Compton scattering of photons increases and there is a high probability of scattered photons reaching the detector. These scattered photons are more energetic and more likely to escape from the object. Maltz et al [1] have used beam stop arrays for scatter correction Such methods increase the X-ray exposure due to more than one scan per projection and extended scanning time. We have applied scatter correction by continuously thickness adapted Scatter Kernel Superposition (SKS) method [5] on a data produced by 9 MeV X-ray photon beam generated from a linear accelerator

Scatter correction using a continuous SKS approach
Kernel generation with MNCP6
Iterative Scatter Correction
RESULTS
CONCLUSIONS
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.