Abstract

Purpose : The purpose of this article is to evaluate a pencil-beam dose calculation algorithm for protons and heavier charged particles in complex patient geometries defined by computed tomography (CT) data and to compare isodose distributions calculated with the new technique to those calculated with conventional algorithms in selected patients with skull-base tumors. Methods and Materials : Monte Carlo calculations were performed to evaluate the pencil-beam algorithm in patient geometries for a modulated 150-MeV proton beam. A modified version of a Mont Carlo code described in a previous publication (18) was used for these comparisons. Tissue densities were inferred from patient CT data on a voxel-by-voxel basis, and calculations were peformed with an without tissue compensators. A dose calculation module using the new algorithm was written, and treatment plans using the new algorithm were compared to plans using standard ay-tracing techniques for 10 patients with clival chordoma and three patients with nasopharyngeal carcinoma who were treated with helium ions at Lawrence Berkeley National Laboratory (LBL). Results : Pencil beam calculations agreed well with Monte Carlo calculations in the patient geometries. The pencil-beam algorithm predicted several multiple-scattering effects that are not modeled by conventional ray-tracing calculations. These includes (a) the widening of the penumbra as a function of beam penetration, (b) the degradation in the sharpness of the dose gradient at the end of the particle range in hgihly heterogeneous regions, and (c) the appearance of hot and cold dose regions in the shadow of cmplex heterogeneities. In particular, pencil-beam calculations indicated that the dose distribution within the target was not a homogeneous as expected on the basis of ray-tracing calculations. on average, for the 13 patients considered, only about 72% of the cone down target volume received at least 99% of the prescribed dose, whereas, 93% of the conedwn volume was contained within the 95% isodose surface. This may e significant because in standard charged particle dose calculations, the dose across the spread-Bragg peak is assumed to be uniform and equal to the maximum or prescribed dose. Conclusions : Dose distributions computed with the pencil-beam model are more accurate than ray-tracing calculations, providing additional information to clinicians, which may influence the doses they prescribe. In particular, these calculations indicate that for some patients with skull-base tumors, it may be advantageous to prescribe proton doses to a lower isodose level than is commonly done.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.