IntroductionThe assessment of spinal deformities with rasterstereography can enhance the understanding, as well as can reduce the number of x-rays needed. However, to date this technique only allows measurements under static conditions. Since it would be of great value to be able to also analyze the spine in dynamic conditions, the present study evaluated a novel rasterstereographic system.Materials and MethodsA new rasterstereographic device was evaluated in a comparison with the gold standard in motion analysis, the VICON system. After initial testing using 12 flat infrared markers adhered to a solid plate, the two systems were evaluated with the markers adhered onto the backs of 8 test subjects. Four triangles were defined using the markers, and the sides of each triangle were measured under static and dynamic conditions.ResultsOn the solid plate, the sides of the 4 triangles were measured with a measuring tape and then by the two optical systems. Rasterstereography showed a high accuracy in marker detection on the solid plate. Under dynamic conditions, with the subjects walking on a treadmill, the rasterstereographically-measured side lengths were compared with the lengths measured by the VICON system as an assessment of marker detection. No significant differences (p>0.05) were found between the systems, differing only 0.07–1.1% for all sides of the four triangles with both systems.DiscussionA novel rasterstereographic measurement device that allows surface and spine topography under dynamic conditions was assessed. The accuracy of this system was with one millimeter on a solid plate and during dynamic measurements, to the gold standard for motion detection. The advantage of rasterstereography is that it can be used to determine a three-dimensional surface map and also allows the analysis of the underlying spine.

Highlights

  • The assessment of spinal deformities with rasterstereography can enhance the understanding, as well as can reduce the number of x-rays needed

  • Rasterstereography showed a high accuracy in marker detection on the solid plate

  • With the subjects walking on a treadmill, the rasterstereographically-measured side lengths were compared with the lengths measured by the VICON system as an assessment of marker detection

Read more

Summary

Introduction

The assessment of spinal deformities with rasterstereography can enhance the understanding, as well as can reduce the number of x-rays needed To date this technique only allows measurements under static conditions. Further research led to the invention of ultrasound or optical surface scanners, such as the Zebris, Quantec or Inspeck system, which allow a radiation-free and three-dimensional analysis of the back surface [9,10,11] Most of these systems use the position of markers, placed on anatomical landmarks on the back surface, to reconstruct the spinal posture with adequate accuracy. These systems often require a trained operator because of the rather complicated setup of the components and placement of multiple surface markers on the back In addition these systems do not allow a reconstruction of the underlying spine, which limits the use of these devices in many cases to experimental or research purposes [7]

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.