Abstract
Falciparum malaria is a fatal infection without immediate diagnosability or treatment. There are shortages of clinicians and examiners skilled in the treatment of malaria in non-endemic countries, including Japan. This study was performed to evaluate a novel rapid molecular diagnostic system consisting of loop-mediated isothermal amplification (LAMP) combined with DNA filter paper (FTA card) and melting curve analysis. Combining LAMP with melting curve analysis enabled diagnosis of Plasmodium falciparum more accurately with relative ease. FTA cards could be used to clarify problems regarding storage, infectivity, and transportation. The LAMP assay was carried out at a constant temperature of 63ºC for 90 min. The diagnostic system (malaria-LAMP) accurately diagnosed malaria (47 samples from Thailand and 50 from Zimbabwe) with 97.8% sensitivity and 85.7% specificity as compared with microscopic methods, indicating the usefulness of this combined system.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.