Abstract
A metallurgical evaluation was performed to investigate a crack in a lateral water wall boiler tube. The 2.5-in. diameter, carbon-steel tube was removed from a 125 MW coal-fired boiler used for base load electric power generation. Visual examination, microstructure characterization, and SEM/EDS analysis were used to determine that hydrogen damage was the primary failure mechanism.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.