Abstract

Respiratory motion compensation in PET/CT and PET/MRI is essential as motion is a source of image degradation (motion blur, attenuation artifacts). In previous work, we developed a direct method for joint image reconstruction/motion estimation (JRM) for attenuation-corrected (AC) respiratory-gated PET, which uses a single attenuation-map (μ-map). This approach was successfully implemented for respiratory-gated PET/CT, but since it relied on an accurate μ-map for motion estimation, the question of its applicability in PET/MRI is open. The purpose of this work is to investigate the feasibility of JRM in PET/MRI and to assess the robustness of the motion estimation when a degraded μ-map is used. We performed a series of JRM reconstructions from simulated PET data using a range of simulated Dixon MRI sequence derived μ-maps with wrong attenuation values in the lungs, from -100% (no attenuation) to +100% (double attenuation), as well as truncated arms. We compared the estimated motions with the one obtained from JRM in ideal conditions (no noise, true μ-map as an input). We also applied JRM on 4 patient datasets of the chest, 3 of them containing hot lesions. Patient list-mode data were gated using a principal component analysis method. We compared SUVmax values of the JRM reconstructed activity images and non motion-corrected images. We also assessed the estimated motion fields by comparing the deformed JRM-reconstructed activity with individually non-AC reconstructed gates. Experiments on simulated data showed that JRM-motion estimation is robust to μ-map degradation in the sense that it produces motion fields similar to the ones obtained when using the true μ-map, regardless of the attenuation errors in the lungs (< 0.5% mean absolute difference with the reference motion field). When using a μ-map with truncated arms, JRM estimates a motion field that stretches the μ-map in order to match the projection data. Results on patient datasets showed that using JRM improves the SUVmax values of hot lesions significantly and suppresses motion blur. When the estimated motion fields are applied to the reconstructed activity, the deformed images are geometrically similar to the non-AC individually reconstructed gates. Motion estimation by JRM is robust to variation of the attenuation values in the lungs. JRM successfully compensates for motion when applied to PET/MRI clinical datasets. It provides a potential alternative to existing methods where the motion fields are pre-estimated from separate MRI measurements.

Highlights

  • Patient respiratory motion is a source of quantitation errors in positron emission tomography (PET), due to the degradation of the image resolution[1] and potential misalignment phenomena can compromise accurate detection and quantitation of lesions in the reconstructed PET.[4]

  • The activity values are different due to the incorrect l-values, the organ boundaries of ^f x‘ at each gate look similar to the ones of the ideal reconstructed activity images ^f i‘deal (Fig. 1(b)) regardless of x, suggesting that joint image reconstruction/motion estimation (JRM) motion estimation is not affected by the lung l-value defects

  • For the current choice of B-spline parametrization and penalty, that when the lung attenuation error does not exceed Æ50% the difference is negligible, and does not exceed 0.45% with Æ100% error. This shows that the impact of the deterioration the l-values on motion estimation by JRM is limited for reasonable errors on the l-map

Read more

Summary

Introduction

Patient respiratory motion is a source of quantitation errors in positron emission tomography (PET), due to the degradation of the image resolution[1] and potential misalignment phenomena can compromise accurate detection and quantitation of lesions in the reconstructed PET.[4]. A single reference activity image is estimated together with the motion by performing penalized maximum-likelihood (PML) of the PET data Such approaches have been proposed in the literature[13,14,15,16] but they ignored attenuation. This approach incorporates l-map misalignments within the motion so that the final output activity image is free of attenuation artifacts This approach, namely joint activity reconstruction/motion estimation (JRM), was successfully applied on PET/CT patient data.[17]. JRM requires an accurate forward model, and in particular an estimate of the attenuation that can be deformed to fit each respiratory gate This raises the question of its applicability in PET/MR. We applied JRM on four sets of respiratory-gated PET/MRI clinical data, Medical Physics, 0 (0), xxxx and investigated the effects of JRM motion compensation on hot lesions, as well as comparing the JRM reconstructed images with non-AC individually reconstructed gates

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call