Abstract

The objective of this study was to evaluate the utility of a digital Brix refractometer for the assessment of success of passive transfer of maternal immunoglobulin compared with the measurement of serum total protein (STP) by refractometry. Blood samples (n=400) were collected from calves at 3 to 6d of age. Serum IgG concentration was determined by radial immunodiffusion (RID), and STP and percentage Brix (%Brix) were determined using a digital refractometer. The mean IgG concentration was 24.1g/L [standard deviation (SD) ± 10.0] with a range from 2.1 to 59.1g/L. The mean STP concentration was 6.0g/dL (SD ± 0.8) with a range from 4.4 to 8.8g/dL. The mean %Brix concentration was 9.2% (SD ± 0.9) with a range of 7.3 to 12.4%. Brix percentage was highly correlated with IgG (r=0.93). Test characteristics were calculated to assess failure of passive transfer (FPT; serum IgG <10g/L). The sensitivity and specificity of STP at 5.5g/dL were 76.3 and 94.4%, respectively. A receiver operating characteristic curve was created to plot the true positive rate against the false positive rate for consecutive %Brix values. The optimal combination of sensitivity (88.9%) and specificity (88.9%) was at 8.4% Brix. Serum total protein was also positively correlated with %Brix (r=1.00) and IgG (r=0.93). Dairy producers can successfully monitor their colostrum management and the overall success of passive transfer using a digital Brix refractometer to estimate IgG concentration of colostrum and calf serum.