Abstract

An evaluation of the complete scheme and data for 233Pa decay, including results of the recent measurements, is presented. Several data evaluation procedures were used in the analysis of the half-life data. The half-life has been determined to be 26.971±0.013 days. All the gamma-ray emission probabilities ever published have been examined, and the gamma-ray emission probability for the reference 312-keV γ line is recommended as 38.35±0.28%. The calculated internal conversion coefficients and their uncertainties have been used to obtain the complete decay intensity balance. Other decay characteristics have been calculated using the ENSDF analysis program. Finally, a new 233Pa decay scheme has been built.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.