Abstract

The aim of the study was to evaluate the efficacy and complication rate with use of 2.0-mm titanium three-dimensional (3D) curved angle strut plate for mandibular angle fractures. Twenty cases requiring internal fixation of the mandibular angle by 2.0-mm titanium 3D curved angle strut plates were evaluated. Postoperative clinical and radiological analyses were done on 1st, 2nd, 4th, and 6th weeks, which included wound healing, transmitted movements, difficulty in function and occlusion, and neurosensory changes, if any. Reasonable level of success in terms of immediate jaw function was noted in all cases. Transient inferior alveolar nerve dysfunction was observed in three cases, which recovered gradually in 2 months, and surgical site infection was observed in two cases, which resolved with appropriate course of antibiotics and wound care. Fixation of mandibular angle fractures with a 2.0-mm titanium 3D curved angle strut plate is predictable, expeditious, and has less complication rate.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.