Abstract
The technique of monitoring the conditions of a fçgade system as part of the scientific and technical support of construction. The building demands an increased level of responsibility. Facade systems “ZIAS-100.02” with cladding with fiber cement slabs and “ZIAS-100.02” with cladding with concrete slabs are used during the construction. Monitoring of the system is carried out in order to verify the compliance of the facade fencing with the requirements of design documentation, applicable standards and requirements, as well as to determine and evaluate the actual condition of the facade system. Selective tests of anchor dowels of sizes 10x135 and 10x100 mm used in hinged facade systems were completed as part of the monitoring. The tests were carried out after a visual inspection of the facade system structures. During the tests, the ONIKS-1.VD.050 material strength meter was used. Anchor dowels were pulled out from two types of walls. The first type of walls is made of foam concrete blocks, the second type of monolithic reinforced concrete. The results of tests for two types of walls are presented. A variant of processing the individual results of the breaking load values obtained during the testing of anchor dowels of the facade system is also shown.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IOP Conference Series: Materials Science and Engineering
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.