Abstract

The purpose of this research is to propose a method for evaluating the time-dependent corrosion behavior of carbon steel plates using an atmospheric corrosion monitor (ACM) corrosion sensor consisting of a Fe/Ag-galvanic couple. Atmospheric exposure tests were carried out on steel plates for periods of 6, 12, and 24-months on the island of Okinawa in Japan. The Specimens were mounted on racks at angles of 0, 45 and 90 to the horizontal to obtain corrosion data in various corrosive environments. In addition, the environments of the skyward- and groundward-facing surfaces of the specimens were monitored using ACM sensors. The sensor outputs were recorded during the exposure tests.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.