Fine mesh sieve technologies were tested in full scale at several municipal wastewater treatment plants. A screening test was used to characterize wastewater and establish the design criteria for the sieves. To achieve high removal efficiencies it was crucial to operate the sieves with a filter mat. Rotating belt sieves performed best in the full-scale tests. A small dose of cationic polymer and a static flocculator ahead of a rotating belt sieve achieved excellent results on a wastewater that was originally found unsuitable for primary treatment with fine mesh sieves. Simple screw presses dewatered the sludge from the sieves to typically 25-30% total solids. Using fine mesh sieves with <500 microns openings was found to normally be the most economical process for primary treatment.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.