Abstract

For the open loop control system based on the solar position algorithm (SPA), without sensor correction, the error of SPA will bring the tracking error directly to decrease the efficiency of the solar system. By comparing with SPA proposed by NREL, this paper first evaluates main SPAs with different accuracy and presents the error of SPA on tracking error. Based on the annual average efficiency of the solar trough system, this paper evaluates the impact of the tracking error caused by SPA on the solar trough system, and proposes that the average SPA calculation error can be applied to characterize the impact of SPA on the trough solar system. By making a comparison of solar trough system efficiency calculated with fixed annual average tracking error and normal constantly changing tracking error within a year, respectively, the evaluation results show that for most SPAs, the introduced error is less than 0.05%, and only a few empirical algorithms with large tracking errors introduce larger errors, but they are not suitable for the trough solar system. Therefore, the SPA evaluation method proposed in this paper is applicable to the solar trough system.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.