Abstract

We compared delayed triple-dose gadolinium (Gd) (0.3 mmol/kg) T1-weighted (D3x-T1), triple-dose fluid-attenuated inversion-recovery fast spin-echo (fast-FLAIR) (3x-FF) and routine single-dose Gd (0.1 mmol/kg) T1-weighted (1x-T1) images in the detection of central nervous system (CNS) abnormalities in patients with human immunodeficiency virus (HIV) infection. Thirty-three brain MRI scans performed on 29 patients were reviewed by a panel of three neuroradiologists for lesion conspicuity, comparing D3x-T1 with 1x-T1 and D3x-T1 with 3x-FF For each pair of comparisons, the panel reached a consensus about which technique was superior in terms of the number of lesions revealed or lesion conspicuity. Note was made of cases in which a particular technique was judged to alter the radiologic diagnosis. Compared to 1x-T1, D3x-T1 improved lesion detection in 14/29 patients (48%). In three patients (10%), the improvement changed the radiologic diagnosis. Compared to D3x-T1, lesion detection on 3x-FF improved in 19/29 ...