Abstract

Skin corrosion testing is integral to evaluating the potential harm posed by chemicals, impacting regulatory decisions on safety, transportation, and labeling. Traditional animal testing methods are giving way to in vitro alternatives, such as reconstructed human epidermis (RhE) models, aligning with evolving ethical standards. This study evaluates the QileX-RhE test system's performance for chemical subcategorization within the OECD TG 431 framework. Results demonstrate its ability to differentiate subcategories, accurately predicting 83% of UN GHS Category 1A and 73% of UN GHS Category 1B/1C chemicals with 100% sensitivity in corrosive prediction. Additionally, this study provides a comprehensive assessment of the test method's performance by employing nuanced parameters such as positive predictive value (PPV), negative predictive value (NPV), post-test odds and likelihood rations, offering valuable insights into the applicability and effectiveness of the QileX-RhE test method.