Abstract
The physical demands on evacuators were investigated when using different types of sled-type stair descent devices designed for the emergency evacuation of high rise buildings. Twelve firefighters used six sled-type stair descent devices during simulated evacuations. The devices were evaluated under two staircase width conditions (1.12, and 1.32 m). Dependent measures included electromyographic (EMG) data, heart rates, Borg Scale ratings, and descent velocities. All stair descent speeds were below those reported during pedestrian egress trials. With the exception of the inflatable device, the devices operated by two evacuators had higher descent speeds than those operated by a single evacuator. High friction materials under the sleds facilitated control and reduced the muscle demands on stairs but increased physical demands on the landings. Usability assessments found devices with shorter overall lengths had fewer wall contacts on the landing, and handles integrated in the straps were preferred by the evacuators.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.