Abstract

The slice compression test (SCT) is used to evaluate interfacial properties by loading/unloading a specimen of the composite between two plates; one has low modulus and the other has high modulus. The specimen used is an epoxy resin, containing a single SiO2 glass fiber, with a 200 μm diameter. The interfacial debonding is monitored by using a microscope and a video camera. Then, the energy release rate is calculated by finite element analysis. From the in-situ observation, it is found that the interface fracture initiates when the radial stress around the fiber changes from compression to tension due to the Poisson's effect (applied stress ⩾40 MPa). The length of the crack is proportional to the stress as the load increases. It is also found analytically that the energy release rates remain constant once the interface fractures, independent of the initial crack length. It is suggested that the critical energy release rate can be appropriated for the interface fracture criterion.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.