Abstract

BackgroundProtective ventilation with lower tidal volume (VT) and higher positive end-expiratory pressure (PEEP) reduces the negative additive effects of mechanical ventilation during systemic inflammatory response syndrome. We hypothesised that protective ventilation during surgery would affect the organ-specific immune response in an experimental animal model of endotoxin-induced sepsis-like syndrome.Methods30 pigs were laparotomised for 2 hours (h), after which a continuous endotoxin infusion was started at 0.25 micrograms × kg−1 × h−1 for 5 h. Catheters were placed in the carotid artery, hepatic vein, portal vein and jugular bulb. Animals were randomised to two protective ventilation groups (n = 10 each): one group was ventilated with VT 6 mL × kg−1 during the whole experiment while the other group was ventilated during the surgical phase with VT of 10 mL × kg−1. In both groups PEEP was 5 cmH2O during surgery and increased to 10 cmH2O at the start of endotoxin infusion. A control group (n = 10) was ventilated with VT of 10 mL × kg−1 and PEEP 5 cm H20 throughout the experiment. In four sample locations we a) simultaneously compared cytokine levels, b) studied the effect of protective ventilation initiated before and during endotoxemia and c) evaluated protective ventilation on organ-specific cytokine levels.ResultsTNF-alpha levels were highest in the hepatic vein, IL-6 levels highest in the artery and jugular bulb and IL-10 levels lowest in the artery. Protective ventilation initiated before and during endotoxemia did not differ in organ-specific cytokine levels. Protective ventilation led to lower levels of TNF-alpha in the hepatic vein compared with the control group, whereas no significant differences were seen in the artery, portal vein or jugular bulb.ConclusionsVariation between organs in cytokine output was observed during experimental sepsis. We see no implication from cytokine levels for initiating protective ventilation before endotoxemia. However, during endotoxemia protective ventilation attenuates hepatic inflammatory cytokine output contributing to a reduced total inflammatory burden.

Highlights

  • Protective ventilation with lower tidal volume (VT) and higher positive end-expiratory pressure (PEEP) reduces the negative additive effects of mechanical ventilation during systemic inflammatory response syndrome

  • Two animals from the Prot-5 h group died in association with pulmonary hypertension induced by endotoxemia [12] and replaced by other animals

  • Circulatory deterioration was manifested by an increase in mean pulmonary arterial pressure (MPAP) and decreases in cardiac index (CI) and mean arterial blood pressure (MAP)

Read more

Summary

Introduction

Protective ventilation with lower tidal volume (VT) and higher positive end-expiratory pressure (PEEP) reduces the negative additive effects of mechanical ventilation during systemic inflammatory response syndrome. Protective ventilation (PV), i.e. the reduction of biotrauma by the use of small tidal volumes and appropriate positive end-expiratory pressure (PEEP), Sperber et al BMC Pulmonary Medicine (2015) 15:60 contribution of cytokines from individual organs to the systemic picture. The mechanistic relation, complicated because of the pleiotropic function of cytokines, between the pro-inflammatory IL-6 and organ dysfunction has recently been established in an animal model [7]. These results suggest the possible use of cytokine levels as correlative biomarkers and as clinical targets

Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call