Abstract
Further miniaturization of electronic systems is approaching new limits due to the failure mechanism of electromigration. Electromigration results in a transport of material in solder joints subjected to high electrical current densities. This decreases the system reliability and, therefore, it is necessary to assess and quantify this failure mechanism in solder joints. In this paper we discuss the development of new test structures based on modified flip chip structures, which allow monitoring of electromigration effects in lead-free solder joints. The structures are of concave shape which permits shifting of the failure region within the solder joint into a position suitable for deterministic assessment. For example it thus becomes possible to create a nearly homogeneous distribution of current density in the local failure region remote from interfering Inter-Metallic Compounds (IMCs) and material interfaces. Moreover, a smaller electric current is required to reach high current densities, so that Joule heating decreases. As a result the effects of overlying failure mechanisms are reduced to two main factors of influence, namely current density and temperature. Experiments using SnAg3.5 solder joints have been conducted at temperatures from 100°C to 150°C and current densities from 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">4</sup> A/cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> to 7.7×10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">4</sup> A/cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> . Joule heating is evaluated by finite element analysis (FEA) and measured during experiment. The activation energy is found to be 1.32 eV. A scanning electron microscope (SEM) is used to analyze failure characteristics of the structures and a direct comparison of the impacts of electromigration and thermomigration is performed. The results demonstrate the advantages mentioned before and qualify the structures for electromigration research.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.