Abstract
The bonding condition of the spray on foam insulation (SOFI) used to insulate the external tank of the NASA space shuttle can be found by using the audio frequency sound absorption coefficient. The ASTM E1050 standard method for sound absorption measurements was used with an open-ended 1-in-diam cast acrylic impedance tube sealed to the SOFI with closed cell PVC foam. Two artificially disbonded locations, measuring 1.0 in. by 5.5 in. by 0.0625 in. and 2.0 in. by 8.0 in. by 0.0625 in., were detected by peaks in the sound absorption coefficient spectrum. The peaks in the sound absorption spectrum between 1000 and 4000 Hz were 25% to 50% higher over disbonded areas when compared to bonded locations. The maximum and minimum sound absorption levels for the foam ranged between approximately 0.1 and 0.3. The entire sample was scanned using the sound absorption peaks as indicators. Samples of 2-in.-thick polystyrene foam were used with different sized defects at different locations in the foam to relate defect size and location to peaks in absorption coeffi-cient spectrum. [Work supported by NASA under Award No. NAG102098.]
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.