Abstract

AbstractBioretention cells, which are generally effective in controlling surface runoff and recharging groundwater, have been widely adopted as low impact development practices. However, shallow groundwater has limited their implementation in some locations due to the potential problems of a reduction in surface runoff control, groundwater pollution, and continuous groundwater drainage through the underdrain. Many guidelines have established minimum requirements for the groundwater depth below bioretention cells, but they may not be optimized for certain environmental conditions and bioretention cell designs. This study made use of a variably saturated flow model to examine the hydrologic performance of a single bioretention cell in shallow groundwater with event‐based simulations, considering a wide range of initial groundwater depths, media and in situ soil types, surface runoff loads, and underdrain sizes. Performance indicators (e.g., runoff reduction, time for infiltrated water to reach the bioretention cell bottom and the groundwater table, and height and dissipation time of groundwater mound) were evaluated to examine the processes of runoff generation, the formation and dissipation of groundwater mounds, and the bioretention cell's performance in a shallow groundwater environment. The most influential factors were the initial groundwater depth, the hydraulic conductivity of the media soil, and the rainfall runoff load. With a deeper initial groundwater table, infiltrated water took longer to reach the bioretention cell bottom and groundwater table. Groundwater mounds, however, took longer to dissipate even though they were smaller. The groundwater quality can be better protected if relatively less‐permeable soil types (e.g., sandy loam) are used as the media, although it may compromise the performance in runoff quantity control. However, only very high surface runoff loads would cause concerns regarding a reduction in runoff quantity control and possible groundwater contamination due to the shallow groundwater. A distance of 1.5–3 m between the bioretention cell bottom and the groundwater table is generally sufficient. The results of this study could help to guide the planning and design of bioretention cells in areas of shallow groundwater.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.