Abstract

In a polymer electrolyte fuel cell (PEFC) stack, the end cells immediately adjacent to the end plates of a stack usually exhibit different cell behaviors compared to its intermediate cells. In this study, cold-start behaviors of end and intermediate cells in a fuel cell stack are numerically examined by using the three-dimensional cold-start PEFC model. The cold-start simulations show that the ice fraction in the end cell grows much faster than in the intermediate cell, indicating that the heat loss through stack end plate to the ambient is critical, determining the fate of cold-start whether cell shutdown or successful startup. As a consequence, under the assumed cold-start condition (start-up from −20°C and 100mA/cm2), the end cell experiences a sudden voltage drop and cold-start failure due to considerable ice filling in the cathode catalyst layer (CL) whereas a successful startup is achieved in the intermediate cell because its temperature increases faster than the rate of ice growth and finally exceeds freezing temperature.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.