Abstract

Vertical ship lifts (VSLs) are widely used in navigation facilities worldwide because of their efficiency and low cost. Although several researchers have investigated fire evacuation strategies for reducing potential safety hazards in VSLs, an effective and integrated application of stairs and elevators when a fire occurs in a VSL is necessary. Several evacuation routes were analyzed according to VSL structure and evacuation times in this study. Objective function corresponding to the minimum vertical evacuation time and related simulation model was subsequently developed to obtain a cooperative evacuation plan considering different numbers of evacuees. The Three Gorges ship lift was used as an example, and simulation results indicate that number of evacuees and exit selection are the main influencing factors of the total evacuation time in the stair- and elevator-coordinated evacuation mode. Furthermore, the distance between people trapped in ship reception chamber and evacuation exits affects evacuees’ choice of exits. The proposed model can provide a theoretical reference for evacuation research during initial fire events in VSLs.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.